Rose-electronics Vista Remote 2 Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Komunikace Rose-electronics Vista Remote 2. Rose Electronics Vista Remote 2 User Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 72
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
Vista Remote 2
SINGLE USER REMOTE KVM ACCESS OVER IP
10707 Stancliff Road
Houston, Texas 7709
Phone: (281) 933-7673
www.rose.com
INSTALLATION
AND
OPERATIONS MANUAL
Zobrazit stránku 0
1 2 3 4 5 6 ... 71 72

Shrnutí obsahu

Strany 1 - Vista Remote 2

Vista Remote 2SINGLE USER REMOTE KVM ACCESS OVER IP10707 Stancliff RoadHouston, Texas 7709Phone: (281) 933-7673www.rose.com INSTALLATION AND OPERATIO

Strany 2

OVERVIEW 4 Vista Remote 2 Installation and Operations Manual System Overview Vista Remote 2 is a versatile and powerful product that can extend the r

Strany 3 - LIMITED WARRANTY

Vista Remote 2 Installation and Operations Manual 5 Vista Remote 2 Models (Part Number KVL-1R4UA/OV/2) Connector

Strany 4

INSTALLATION 6 Vista Remote 2 Installation and Operations Manual Vista Remote 2 Installation Installing the Vista Remote 2 is a very easy process and

Strany 5 - TABLE of CONTENTS

Vista Remote 2 Installation and Operations Manual 7 Connecting the Computers Connect each computer to the Vista Remote 2 using the appropriate CPU

Strany 6

UNIT CONFIGURATION 8 Vista Remote 2 Installation and Operations Manual Configuring the Vista Remote 2 IP Input module When you locally connect to Vis

Strany 7 - System Introduction

Vista Remote 2 Installation and Operations Manual 9 Hardware The hardware version level is displayed in this field. Firmware The Vista Remote 2 firm

Strany 8 - Package contents

NETWORK CONFIGURATION 10 Vista Remote 2 Installation and Operations Manual Configuring the Network Figure 7. Network Configuration MAC address Medi

Strany 9 - Rose Electronics web site

Vista Remote 2 Installation and Operations Manual 11 Screen #3 is a secure keys screen that will display after the network information has been ente

Strany 10 - System Overview

12 Vista Remote 2 Installation and Operations Manual To view the menu options press <CTRL> <ALT> <C>. (If the default hotkeys wer

Strany 11 - Vista Remote 2 Models

Vista Remote 2 Installation and Operations Manual 13 Configuration Select the “Configuration” tab to gain access to the Unit and Network configurati

Strany 13 - Connecting to the network

14 Vista Remote 2 Installation and Operations Manual Remote Configuration Connect remotely to the Vista Remote 2 unit from any network workstation.

Strany 14 - UNIT CONFIGURATION

Vista Remote 2 Installation and Operations Manual 15 User Accounts Selecting user accounts will display the following menu. Figure 12. User Account

Strany 15

16 Vista Remote 2 Installation and Operations Manual Unit Configuration The ‘Unit Configuration “option tab will display the following menu. Hard

Strany 16 - NETWORK CONFIGURATION

Vista Remote 2 Installation and Operations Manual 17 Encryption Three encryption options are available; Always on, Prefer off, Prefer on. The one to

Strany 17

18 Vista Remote 2 Installation and Operations Manual Mouse Latency Allowance This option is used during calibration to account for latency delays (

Strany 18

Vista Remote 2 Installation and Operations Manual 19 Time and Date Configuration Figure 14. Time and Date Configuration Use the left and right arro

Strany 19 - Connecting Remotely

20 Vista Remote 2 Installation and Operations Manual Network Configuration This menu allows you to remotely configure various aspects of the IP port

Strany 20 - Remote Configuration

Vista Remote 2 Installation and Operations Manual 21 IP Gateway This is the address of the device that links the local network the Vista Remote 2 is

Strany 21 - User Accounts

22 Vista Remote 2 Installation and Operations Manual It is recommended that the naming and hot key assignments for each Host Configuration entry mat

Strany 22 - Unit Configuration

Vista Remote 2 Installation and Operations Manual 23 The first three (3) columns show the date the event occurred. The next column is the time the e

Strany 23 - Unit Advanced Configuration

LIMITED WARRANTY Copyright Rose Electronics 2008. All rights reserved. No part of this manual may be reproduced, stored in a retrieval system, or tran

Strany 24

24 Vista Remote 2 Installation and Operations Manual KVM Switch Module Configuration Connect to the unit directly from the local KVM station and log

Strany 25 - Time and Date Configuration

Vista Remote 2 Installation and Operations Manual 25 Change the computer names Selecting “Names” and pressing enter will display the below display.

Strany 26 - Network Configuration

26 Vista Remote 2 Installation and Operations Manual Configure appearance The “Configure appearance” menu allows you to change the foreground and ba

Strany 27 - Host Configuration

Vista Remote 2 Installation and Operations Manual 27 Name fadeout time: This option sets the time when the computer label disappears after switching

Strany 28 - Logging and Status

28 Vista Remote 2 Installation and Operations Manual Configure security Figure 20. Switch module security settings Configuration password: Assig

Strany 29

Vista Remote 2 Installation and Operations Manual 29 If you forget your “Access password”, the person who knows the configure password can enter a n

Strany 30

30 Vista Remote 2 Installation and Operations Manual Configure keyboard type The “Configure keyboard type” menu allows you to change the keyboard ty

Strany 31 - Change the computer names

Vista Remote 2 Installation and Operations Manual 31 Configure miscellaneous This menu allows you to change the maximum computer ports and scan time

Strany 32 - Appearance options:

32 Vista Remote 2 Installation and Operations Manual Save The “Save” function, saves all configuration changes that have been made to flash memory.

Strany 33

OPERATION Vista Remote 2 Installation and Operations Manual 33 Remote System Operation Connecting using a web browser Connecting to the Vista Remote

Strany 34 - Configure security

FCC / IC STATEMENTS, EU DECLARATION OF CONFORMITY FEDERAL COMMUNICATIONS COMMISSION AND INDUSTRY CANADA RADIO-FREQUENCY INTERFERENCE STATEMENTS Thi

Strany 35 - Configure mouse type

34 Vista Remote 2 Installation and Operations Manual Viewer encryption settings The web browser viewers and VNC viewers offer four encryption settin

Strany 36 - Configure keyboard type

Vista Remote 2 Installation and Operations Manual 35 Controls Tab When you click on the “Controls” tab, the below dropdown menu will display. S

Strany 37 - Configure miscellaneous

36 Vista Remote 2 Installation and Operations Manual Video Settings This dialog provides access to all of the key video settings that determine imag

Strany 38

Vista Remote 2 Installation and Operations Manual 37 Host Tab The “Host” tab on the toolbar allows you to easily switch to any CPU port on the uni

Strany 39 - Remote System Operation

38 Vista Remote 2 Installation and Operations Manual commands to instruct the KVM Switch module to exercise an option must be configured to either t

Strany 40 - VNC Viewer Toolbar

Vista Remote 2 Installation and Operations Manual 39 Keyboard Commands Keyboard commands can be used to further customize the KVM switch module. Th

Strany 41 - Controls Tab

40 Vista Remote 2 Installation and Operations Manual Command Key Description Computer Select <Ctrl> x +-ctrl+-x (x = 1, 2, 3, 4, 5, 6

Strany 42

Vista Remote 2 Installation and Operations Manual 41 change the Scan Time to another interval press and release the left <Ctrl> key, type “T”

Strany 43 - Host Tab

TROUBLESHOOTING 42 Vista Remote 2 Installation and Operations Manual Troubleshooting Remote network users are unable to contact the unit  Check that

Strany 44

Vista Remote 2 Installation and Operations Manual 43 Computer does not boot, keyboard or mouse error received.  Cable is loose, reseat cable and

Strany 45 - Keyboard Commands

TABLE of CONTENTS Contents Page # System Introduction

Strany 46 - Keyboard command description

44 Vista Remote 2 Installation and Operations Manual Video fuzzy  Cable too long or wrong type. Verify that resolution and distance match. See Ap

Strany 47

SERVICE and SUPPORT Vista Remote 2 Installation and Operations Manual 45 Maintenance and Repair This Unit does not contain any internal user-service

Strany 48 - Troubleshooting

SAFETY 46 Vista Remote 2 Installation and Operations Manual Safety This Unit has been tested for conformance to safety regulations and requirements,

Strany 49

Vista Remote 2 Installation and Operations Manual47Safety and EMC Regulatory StatementsSafety InformationDocumentation reference symbol. If the produc

Strany 50

APPENDICES 48 Vista Remote 2 Installation and Operations Manual Appendix A – General specifications Dimensions Width Depth Height 4 / 8 port 16.7”

Strany 51 - Technical Support

Vista Remote 2 Installation and Operations Manual 49 Appendix C – RackMount The rack mount kit includes the following items:  Two black anodized

Strany 52 - Caution!

50 Vista Remote 2 Installation and Operations Manual Appendix D – IP Access Control Setting IP access control The golden rule with this feature is

Strany 53 - Servicing

Vista Remote 2 Installation and Operations Manual 51 Address ranges Although you can define ranges of addresses, due to the way the mask operates,

Strany 54 - Appendix B – Part Numbers

52 Vista Remote 2 Installation and Operations Manual Access Use the arrow buttons to select either ‘Allow’ or ‘Deny’ as appropriate. 1 Enter the ba

Strany 55 - Appendix C – RackMount

Vista Remote 2 Installation and Operations Manual 53 Color/Encoding Auto select When ticked, this option will examine the speed of your connection

Strany 56

Figures Page # Figure 1. Vista Remote 2 Models ...

Strany 57

54 Vista Remote 2 Installation and Operations Manual Scaling No Scaling No attempt is made to make the screen image fit the viewer window. You may

Strany 58

Vista Remote 2 Installation and Operations Manual 55 Misc Shared connection (do not disconnect other viewers) This option does not apply to Vista

Strany 59 - Color/Encoding

56 Vista Remote 2 Installation and Operations Manual Identities This feature helps your VNC viewer to confirm that a revisited Vista Remote 2 unit

Strany 60 - Scaling

Vista Remote 2 Installation and Operations Manual 57 Load / Save Configuration File - Reload Allows you to load a configuration file saved from th

Strany 61

58 Vista Remote 2 Installation and Operations Manual Appendix E – VNC viewer window options Click the VNC icon in the top left corner of the viewer

Strany 62 - Identities

Vista Remote 2 Installation and Operations Manual 59 Appendix F – Browser viewer options When you are connecting to the Vista Remote 2 unit using a

Strany 63 - Load / Save

60 Vista Remote 2 Installation and Operations Manual Inputs View only (ignore mouse & keyboard) When ticked, the viewer will not send keyboard

Strany 64

Vista Remote 2 Installation and Operations Manual 61 Appendix G – Supported video modes The following video modes are supported and can be automati

Strany 65

62 Vista Remote 2 Installation and Operations Manual Appendix H – Typematic Rate Typematic Command Press the left <Ctrl> key, type “A”, enter

Strany 66 - Security

Vista Remote 2 Installation and Operations Manual 63 Appendix I – Hot Key Codes These codes are used when defining hotkey switching sequences (macr

Strany 67

INTRODUCTION Vista Remote 2 Installation and Operations Manual 1 System Introduction Thank you for choosing Vista Remote™ 2 from Rose Electronics for

Strany 68 - Appendix H – Typematic Rate

NOTES 64 Vista Remote 2 Installation and Operations Manual

Strany 70

10707 Stancliff Road Phone: (281) 933-7673 Houston, Texas 77099

Strany 71

2 Vista Remote 2 Installation and Operations Manual Features  Models available: 4-port model 8-port model  Solid-state embedded unit, h

Strany 72

Vista Remote 2 Installation and Operations Manual 3 Rose Electronics web site Visit our web site at www.rose.com for additional information on Vis

Komentáře k této Příručce

Žádné komentáře