Rose electronics Xtensys Manuál s instrukcemi

Procházejte online nebo si stáhněte Manuál s instrukcemi pro Přepínače KVM Rose electronics Xtensys. Rose electronics Xtensys Instruction manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 48
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
Xtensys UNIVERSAL MATRIX CONSOLE SWITCH
10707 Stancliff Road Phone: (281) 933-7673
Houston, Texas 77099 WWW.ROSE.COM
INSTALLATION
AND
OPERATIONS MANUAL
Preliminary Manual Release 11/30/2006
Zobrazit stránku 0
1 2 3 4 5 6 ... 47 48

Shrnutí obsahu

Strany 1 - OPERATIONS MANUAL

Xtensys UNIVERSAL MATRIX CONSOLE SWITCH 10707 Stancliff Road Phone: (281) 933-7673 Houston, Texas 77099 WWW.ROSE.COM INSTALLATION AND OP

Strany 2

MODELS XTENSYS INSTALLATION AND OPERATIONS MANUAL 4 Xtensys models (front) Models Description / Indicators User station Power / Status Indicators

Strany 3 - LIMITED WARRANTY

XTENSYS INSTALLATION AND OPERATIONS MANUAL 5 Xtensys models (rear) Models Description / Connectors User station Power: ICE 320 receptacle Link:

Strany 4

SITE PLANNING XTENSYS INSTALLATION AND OPERATIONS MANUAL 6 System Overview The Xtensys switch is designed with the latest in KVM switching technolog

Strany 5 - TABLE of CONTENTS

XTENSYS INSTALLATION AND OPERATIONS MANUAL 7 System security Security is a very important concern, especially in the environments most Xtensys switc

Strany 6 - Appendices

INSTALLATION XTENSYS INSTALLATION AND OPERATIONS MANUAL 8 Switch installation – Single unit The basic installation of a single Xtensys switch

Strany 7 - INTRODUCTION

MENU SYSTEM XTENSYS INSTALLATION AND OPERATIONS MANUAL 9 Menu Structure Xtensys Menu Structure System settings Computer name KVM name

Strany 8 - Features

XTENSYS INSTALLATION AND OPERATIONS MANUAL 10 Menu System Main Menu Figure 4. Main configuration menu Save all changes made. If not saved, change

Strany 9 -  The Xtensys switch

XTENSYS INSTALLATION AND OPERATIONS MANUAL 11Configure system Figure 5. Configure system menu Selecting “System” from the main menu displays the “

Strany 10 - MODELS

XTENSYS INSTALLATION AND OPERATIONS MANUAL 12 PC keyboard rate (chars/sec) (Default: 20) This option adjusts the KVM keyboard action when you hold d

Strany 11 - Xtensys models (rear)

XTENSYS INSTALLATION AND OPERATIONS MANUAL 13Background color / Text color (Default: Background = Cyan / Text = Black) This option sets the backgrou

Strany 13 - Site planning

XTENSYS INSTALLATION AND OPERATIONS MANUAL 14 Configure computers Figure 6. Configure computer menu The “Configure computer” menu allows you to cha

Strany 14

XTENSYS INSTALLATION AND OPERATIONS MANUAL 15Configure KVM Figure 7. Configure KVM menu The “Configure KVM” menu allows you to change each selecte

Strany 15 - MENU SYSTEM

XTENSYS INSTALLATION AND OPERATIONS MANUAL 16 User (Default: User xx) This field is used to assign a specific user to a KVM station. To change the

Strany 16 - Menu System

XTENSYS INSTALLATION AND OPERATIONS MANUAL 17Configure user Figure 8. Configure user menu The configure user menu is used to define a user name, as

Strany 17 - J Left Ctrl

XTENSYS INSTALLATION AND OPERATIONS MANUAL 18 Configure Profile Figure 9. Configure profile menu The configure profile menu is used to assign compu

Strany 18

XTENSYS INSTALLATION AND OPERATIONS MANUAL 19Scan (Default: 5 seconds) When a user invokes the scan function, this feature sets the time the video i

Strany 19

XTENSYS INSTALLATION AND OPERATIONS MANUAL 20 Configure Group Figure 10. Configure group menu The configure group menu allows you to assign a compu

Strany 20

XTENSYS INSTALLATION AND OPERATIONS MANUAL 21Configure language Figure 11. Configure language menu Selecting “Language” from the “Main” menu displa

Strany 21

XTENSYS INSTALLATION AND OPERATIONS MANUAL 22 System status The system status display is a very powerful and useful tool for monitoring, troubleshoo

Strany 22

XTENSYS INSTALLATION AND OPERATIONS MANUAL 23The computer status display reports the firmware version (FM column) of the CATx transmitter connected

Strany 23

LIMITED WARRANTY Copyright  Rose Electronics 2006. All rights reserved. No part of this manual may be reproduced, stored in a retrieval system, or tr

Strany 24

XTENSYS INSTALLATION AND OPERATIONS MANUAL 24 Save menu Figure 16. Save menu When changes are made to any configuration, they must be saved in flas

Strany 25

Operating Instructions XTENSYS INSTALLATION AND OPERATIONS MANUAL 25User operating instructions The following instructions apply to all Xtensys switc

Strany 26

XTENSYS INSTALLATION AND OPERATIONS MANUAL 26 Login Control Room User ID Password Figure 17. Login screen Once you have

Strany 27

SERIAL FEATURES XTENSYS INSTALLATION AND OPERATIONS MANUAL 27Serial port usage (RS232) The following procedure for establishing a connection from you

Strany 28

XTENSYS INSTALLATION AND OPERATIONS MANUAL 28 Option 1. Receive new main program or kernel from serial port (This card only) When new main or ke

Strany 29

SERIAL FEATURES XTENSYS INSTALLATION AND OPERATIONS MANUAL 29You may receive one of the following errors during the file transfer function: checksum

Strany 30

SERVICE XTENSYS INSTALLATION AND OPERATIONS MANUAL 30 Service Information Maintenance and Repair This Unit does not contain any internal user-servic

Strany 31 - Operating Instructions

SAFETY XTENSYS INSTALLATION AND OPERATIONS MANUAL 31Safety This Xtensys switch has been tested for conformance to safety regulations and requirement

Strany 32

XTENSYS INSTALLATION AND OPERATIONS MANUAL 32 Safety and EMC Regulatory Statements Informations concernant la sécurité Symbole de référence à la d

Strany 33 - SERIAL FEATURES

TROUBLESHOOTING XTENSYS INSTALLATION AND OPERATIONS MANUAL 33Troubleshooting Computer does not boot, keyboard or mouse error received  CPU cable

Strany 34

FCC/IC STATEMENTS, EU DECLARATION OF CONFORMITY I FEDERAL COMMUNICATIONS COMMISSION AND INDUSTRY CANADA RADIO-FREQUENCY INTERFERENCE STATEMENTS This

Strany 35

APPENDICES XTENSYS INSTALLATION AND OPERATIONS MANUAL 34 Appendix A. Initial factory default settings Function Setting Default value System Passw

Strany 36 - SERVICE

XTENSYS INSTALLATION AND OPERATIONS MANUAL 35Appendix B. General specifications Dimensions 17.0 W x 10.0 D x 1.75 H (in) 43.24W x 25.42D x 4.4H

Strany 37 - SAFETY

XTENSYS INSTALLATION AND OPERATIONS MANUAL 36 Appendix C. Parts and cables KVM Switch Part number Description XTS-V4X8D4 4-Remote Users / 8 CPU’s

Strany 38

XTENSYS INSTALLATION AND OPERATIONS MANUAL 37Appendix D. Quick Start Guide The following guide will help you understand the basic single unit insta

Strany 39 - TROUBLESHOOTING

XTENSYS INSTALLATION AND OPERATIONS MANUAL 38 Step 1 – Connect the User Station(s) Connectors (left to right) (1) RJ45F – Link to Xtensys (4) USB

Strany 40 - APPENDICES

XTENSYS INSTALLATION AND OPERATIONS MANUAL 39Operating procedure With all connections in place and the system powered up, you can connect and fully

Strany 41

XTENSYS INSTALLATION AND OPERATIONS MANUAL 40 Appendix E. Video adjustment keyboard commands These keyboard commands can be used to perform a cable

Strany 43

10707 Stancliff Road Phone: (281) 933-7673 Houston, Texas 77099 WWW.ROSE.COM

Strany 44

TABLE of CONTENTS II Contents Disclaimer...

Strany 45

Figures Figure 1. Models - Front View...

Strany 46

INTRODUCTION XTENSYS INSTALLATION AND OPERATIONS MANUAL 1 Disclaimer While every precaution has been taken in the preparation of this manual, the ma

Strany 47

XTENSYS INSTALLATION AND OPERATIONS MANUAL 2 Features Security  Unique configuration password for persons authorized to perform configuration main

Strany 48

XTENSYS INSTALLATION AND OPERATIONS MANUAL 3 Cable requirements Cabling for the User Station to the Xtensys switch and from the Xtensys switch to al

Komentáře k této Příručce